Appliance certifications and specifications

Make sure an appliance meets regulatory and environment requirements.

SuperMicro-based platforms

SuperMicro certifications
McAfee 1U McAfee 2U or 3U
Electromagnetic emissions

FCC Class B, EN 55022 Class B,

EN 61000-3-2/-3-3

CISPR 22 Class B

FCC Class B, EN 55022 Class B,

EN 61000-3-2/-3-3

CISPR 22 Class B

Electromagnetic immunity

EN 55024/CISPR 24,

(EN 61000-4-2, EN 61000-4-3,

EN 61000-4-4, EN 61000-4-5,

EN 61000-4-6, EN 61000-4-8,

EN 61000-4-11) 55024

EN 55024/CISPR 24,

(EN 61000-4-2, EN 61000-4-3,

EN 61000-4--4, EN 61000-4-5,

EN 61000-4-6, EN 61000-4-8,

EN 61000-4-11) 55024

Safety

EN 60950/IEC 60950-Compliant,

UL Listed (USA)

CUL Listed (Canada)

TUV Certified (Germany)

CE Marking (Europe)

EN 60950/IEC 60950-Compliant,

UL Listed (USA)

CUL Listed (Canada)

TUV Certified (Germany)

CE Marking (Europe)

DAS

DAS certifications
Certification marks ED, NRTL, RCM, KCC, BSMI, IRAM, EAC
Standards certified to EN60950-1, EN55032, EN55024
Regions covered U.S. and Canada, European Union, APAC, LTAM
Other countries with certification Japan, Israel, South Africa, Ukraine, Morocco
DAS specifications
DAS-120, DAS-250
Input voltage 100–240 VAC
Input frequency 50/60 Hz
Power supply 800 W X2
Power consumption

DAS-120 - 331 W

DAS-250 - 663 W

Amps (Max)

10@100-127 VAC

5@200-240 VAC

Altitude (Max) 10,000 ft @ 68º F
Temperature (Max)

0º to 35º C (32º to 95º F) operating

–20º to 60º C (-4º to 140º F) non-operating

BTU

DAS-120 - 1331 BTU/HR

DAS-250 - 2661 BTU/HR

Humidity

Operating — 20% to 80% (non-condensing)

Intel-based platforms

Intel-based 1U specifications
Parameter Limits
Operating temperature +10° C to +35° C with the maximum rate of change not to exceed 10° C per hour
Non-operating temperature –40° C to +70°
Non-operating humidity 90%, non-condensing at 35° C
Acoustic noise Sound Power: 7.0 BA in an idle state at typical office ambient temperature. (23 ± 2 degrees C)
Shock, operating Half sine, 2-g peak, 11 msec
Shock, unpackaged

Trapezoidal, 25 g, velocity change 136 inches/sec (≧ 40 lbs to > 80 lbs)

Shock, packaged

Non-palletized free fall in height 24 inches (≧40 lbs to > 80 lbs)

Shock, operating Half sine, 2-g peak, 11 mSec
Vibration, unpackaged 5 Hz to 500 Hz, 2.20 g RMS random
ESD ±12 kV for air discharge and 8 K for contact
System cooling requirement in BTU/Hr 1660 BTU/hour
Intel-based 2U specifications
Parameter Limits
Temperature Operating
  • ASHRAE Class A2 — Continuous operation. 10°C to 35°C (50°F to 95°F) with the maximum rate of change not to exceed 10°C per hour.
  • ASHRAE Class A3 — Includes operation up to 40°C for up to 900 hrs per year
  • ASHRAE Class A4 — Includes operation up to 45°C for up to 90 hrs per year
Shipping –40°C to 70°C (–40°F to 158°F)
Altitude (Operating) Support operation up to 3050 m with ASHRAE class deratings
Humidity (Shipping) 50% to 90%, non-condensing with a maximum wet bulb of 28°C (at temperatures from 25°C to 35°C)
Shock Operating Half sine, 2 g, 11 mSec
Unpackaged Trapezoidal, 25 g, velocity change is based on packaged weight
Packaged

Product Weight: ≥ 40 to < 80

Non-palletized free fall height = 18 inches

Palletized (single product) free fall height = NA

Vibration 5 Hz to 500 Hz

2.20 g RMS random

Packaged 5 Hz to 500 Hz

1.09 g RMS random

AC-DC Voltage 90 Hz to 132 V and 180 V to 264 V
Frequency 47 Hz to 63 Hz
Source Interrupt No loss of data for power line drop-out of 12 mSec
Surge non-operating and operating Unidirectional